If you are having issues with your T230 room panel, please follow the troubleshooting guide below.
LED colour |
Screen |
Problem due to/ behavior |
Solution |
No lights |
Black |
1. No power 2. Port down in switch. 3. Cable glitch (RJ45 contact). 4. Broken cable. |
1. Check that you have power. 2. Open port. 3. Detach and attach cable and check if contact is broken 4. Make sure cable is not broken
|
Green |
Black |
Turned off |
Try starting the room panel by pressing the reset button in the top for around 10 sec. If that does not help try detach and attach the Ethernet cable. |
Any |
Frozen |
App-crash. |
1. Hold down reset button until screen is black. Detach and attach Ethernet to be able to start panel (restart with paperclip). |
Any |
Slightly wrong time |
Google timeservers cannot be reached. |
Open port 123 for UDP packages |
Any |
Grey and message is “no connection” |
1. No IP address received. 2. No certificate on server. |
1. Log into panel, scroll down and choose “network test”. 2. Contact your IT, to see if certificate is still valid. |
Also try to do a |
Short reset , hold the reset for 5 seconds. |
||
Also try to do a |
Long reset (30 seconds) |
If the above suggestion did not help, please send an email to support@flowscape.se for an RMA request.